B-TEK Concrete Deck Truck Scales Specifications
Posted on May 3, 2016
Standard Sizes: between 10′ x 10′ to 80′ x 11′
Full Electronic Analog
- Certificate of Conformance: 97-116A1
- Scale Capacity: Up to 270,000 lbs.
- Concentrated Load Capacity: 80,000 lbs.
- Scale Height: 36”
- Available Widths: 8’ – 16’
- Weighbridge Deck: 6” concrete deck – deck coping supplied for field installation
- Option: Factory supplied deck sheeting and rebar
- Steel Preparation: Commercial blast cleaning SSPC-SP6
- Paint System: Cross-Linked two-part Epoxy – 2 to 4 mil primer base coat Two-part UV resistant Polyurethane – 2 to 4 mil top coat
- Load Cell: 75K CPR-M analog compression-column load cell, 700 Ohm, 2 mV/V Stainless steel environmentally sealed (IP67) construction
- Load Cell Cable: Stainless steel sheathed cable with clear polymer coating, integral
- Junction Box: NEMA 4X FRP enclosure(s) and B-TEK 4-cell summing board with GDT surge protection
- Surge Protection: CPR-M analog load cells utilize ground straps and base plate isolation disc Surge protection enhanced by Tripp-Lite Isobar Ultra 4-Outlet line transient protection device
- Indicator: Not included with analog cell version
Standard Sizes: between 10′ x 10′ to 80′ x 11′
Full Electronic Digital
- Certificate of Conformance: 97-116A1
- Scale Capacity: Up to 270,000 lbs.
- Concentrated Load Capacity: 80,000 lbs.
- Scale Height: 36”
- Available Widths: 8’ – 16’
- Weighbridge Deck: 6” concrete deck – deck coping supplied for field installation
- Option: Factory supplied deck sheeting and rebar
- Steel Preparation: Commercial blast cleaning SSPC-SP6
- Paint System: Cross-Linked two-part Epoxy – 2 to 4 mil primer base coat Two-part UV resistant Polyurethane – 2 to 4 mil top coat
- Load Cell: 75K CPD-M digital compression column load cell, RS-485 digital output Stainless steel hermetically sealed (IP68) construction
- Load Cell Cable: Stainless steel sheathed cable with clear polymer coating and water-tight connectors
- Junction Box: NEMA 4X stainless steel enclosure(s) and 8-cell terminal board with GDT surge protection
- Surge Protection: CPD-M digital load cells along with Dialogik indicator protect against lightning Built-in surge protection enhanced by Tripp-Lite Isobar Ultra 4-Outlet AC line transient protection device and two in-line serial port surge protection devices
- Indicator: Supplied with a Dialogik D410 desk-top digital indicator (required)
Categories:
Specifications
Manufacturer: B-Tek Scales
Linked To: