Minebea Intec Compression Load Cell Inteco
As digital weighing solution with the converter Connexx, the load cell Inteco offers fast signalling times and optimal transparency in dosing and weighing processes. With an output signal of 2 mV/V, load levels of up to 75 t,accuracy classes up to C6 and high-quality stainless steel, it has a wide range of potential applications.
The versatile, innovative weighing solution for silo and vessel weighing
- Further development of the PR 6201 load cell
- NEW: Output signal of 2 mV/V
- NEW: additional load levels 60 t and 75 t
- NEW: Accuracy class (C6) from 3 t
- NEW: even higher corrosion resistance
- All accessories and installation kits of the PR 6201 load cell can still be used
Manufacturer: Minebea Intec
Types: Digital Load Cells, Digital Load Cells
Industries: Chemical, Food / Beverage
Parameter | Description | Abbr. | D1/N | C3 | C6 | Unit |
Accuracy class | 0.04 | 0.015 | 0,008 | % Emax | ||
Maximum capacity | Highest limit of specified measuring range | Emax | See Ordering information table | See Ordering information table | See Ordering information table | kg |
Safe load limit | Maximum load without irreversible damage | Elim | For 500 kg ¦ 50 t: 150For 60 t: 125For 75 t: 100 | For 500 kg ¦ 50 t: 150For 60 t: 125For 75 t: 100 | For 500 kg ¦ 50 t: 150For 60 t: 125For 75 t: 100 | % Emax |
Destructive load | Danger of mechanical destruction | Ed | For 500 kg ¦ 50 t: >300For 60 t: >250For 75 t: >200 | For 500 kg ¦ 50 t: >300For 60 t: >250For 75 t: >200 | For 500 kg ¦ 50 t: >300For 60 t: >250For 75 t: >200 | % Emax |
Minimum LC verification | Minimum load cell verification interval (vmin = Emax/Y) | See Accuracy classes and minimum verification interval, vmin table | See Accuracy classes and minimum verification interval, vmin table | See Accuracy classes and minimum verification interval, vmin table | ||
For Emax = 500 kg | Y | 2,500 | n.a. | n.a. | ||
For Emax = 1 t | Y | 5,000 | n.a. | n.a. | ||
For Emax = 2 t | Y | 5,000 | 10,000 | n.a | ||
For Emax = 3 t ¦ 75 t | Y | 5,000 | 14,000 | 3 t 10 t: 14,000>20 t: 20,000 | ||
Rated output | Relative output at maximum capacity | Cn | 2 | mV/V |